Drives and Controls

MK5 (CONTROLLER FOR A SINGLE SMOKE OR FIRE CURTAIN)

The MK5 Controller is a control system option for a single Smoke or Fire Curtain. The MK5 system uses Smoke / Fire Curtains with 24Vdc permanent magnet electrical motor fitted with an internal 24Vdc electromagnetic brake, as standard. The MK5 offers a wide range of ancillaries / optional extras, all using simple plug / socket connections.

VIEW MK5 DATASHEET VIEW MK5 WIRING DIAGRAM VIEW MK5 CONNECTION COVER VIEW MK5 BMS INTERFACEVIEW DECLARATION OF CONFORMITYVIEW EC DECLARATION OF CONFORMITY

BBU (BATTERY BACKUP UNIT)

The Variospeed®6 BBU is an electrical control system option and can control up to 20 Smoke / Fire curtains. If there is a mains power failure the Smoke / Fire curtain(s) will be held in the retracted position for 30 minutes (adjustable) under Battery Backup (BBU) before being deployed to their Fire Operational Position (FOP). If an alarm signal is received during a mains power failure, the curtain(s) will deploy immediately to their Fire Operational Position (FOP). The curtain(s) will descend under Total & Controlled GFS (Total Gravity Failsafe).

VIEW BBU CG DATASHEET  VIEW BBU CAM DATASHEET VIEW BBU CG WIRING DIAGRAM VIEW BBU CAM WIRING DIAGRAM VIEW MCU 11W DATASHEET VIEW MCU 30R DATASHEETVIEW DECLARATION OF CONFORMITYVIEW EC DECLARATION OF CONFORMITY

ERU (EMERGENCY RETRACT UNIT)

The Emergency Retract Unit (ERU) has the same functionality as the BBU, however, offers more optional extras, including the emergency retract facility. The emergency retract facility is available during an alarm condition, once the curtains have reached their FOP. The Emergency Retract Facility is also available during a mains failure once the curtain(s) have descended, this can take the form of an Emergency Retract Button or Emergency Access Button. The number of retract operations under mains power failure is limited to the battery power and affected by the size of the curtain(s), number of curtains and any optional extras powered by the ERU.

VIEW ERU CG DATASHEET VIEW ERU CAM DATASHEET view ERU cg wiring diagram VIEW ERU CAM WIRING DIAGRAM VIEW MCU ER DATASHEETVIEW DECLARATION OF CONFORMITYVIEW EC DECLARATION OF CONFORMITY

Horizontal Controllers

The HZ-CG systems are used for Horizontal Smoke / Fire Curtains fitted with 24Vdc permanent magnet electrical motors fitted with an internal 24Vdc electromagnetic brake, as standard. When the Smoke / Fire curtain(s) are fully retracted, the internal electromagnetic brake is powered, keeping the Smoke / Fire curtain(s) in their retracted position. Power to the motor is completely isolated, prolonging the life of the motor.

VIEW HZ-CG DATASHEET VIEW MAXI-HORIZ DATASHEETVIEW EC DECLARATION OF CONFORMITY

UL Control Systems

An electrical control system approved to UL-864 for Smoke/Fire Curtains. If there is a mains power failure the Smoke / Fire curtain(s) will be held in the retracted position for 30 minutes (adjustable) under Battery Backup (BBU) before being deployed to their Fire Operational Position (FOP). If an alarm signal is received during a mains power failure, the curtain(s) will deploy immediately to their Fire Operational Position (FOP). The curtain(s) will descend under Total & Controlled GFS (Total Gravity Failsafe). The emergency retract facility is an option and available during an alarm condition, once the curtains have reached their FOP. The Emergency Retract Facility is also available during a mains failure once the curtain(s) have descended, this can take the form of an Emergency Retract Button or Emergency Access Button. The number of retract operations under mains power failure is limited to the battery power and affected by the size of the curtain(s).

VIEW VS6-UL-MCU/ER DATASHEET VIEW VS6-UL-ERU-CAM DATASHEET

MOTORS

The Variospeed®6 Motor range are permanent magnet electrical motors fitted with an internal 24Vdc electromagnetic brake, as standard. When the Smoke/Fire curtain(s) are fully retracted, the internal electromagnetic brake is powered, keeping the Smoke/Fire curtain(s) in their retracted position. Power to the motor is completely isolated.

VIEW VS6 11w motor VIEW vs6 50G motor VIEW vs6 30R motor